HC1-A-EN变频器使用说明书手册_第1页
HC1-A-EN变频器使用说明书手册_第2页
HC1-A-EN变频器使用说明书手册_第3页
HC1-A-EN变频器使用说明书手册_第4页
HC1-A-EN变频器使用说明书手册_第5页
已阅读5页,还剩99页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

TECORPElectronics HC1-AUserManual

Contents

1.Introduction-----------------------------------------------------11.1Confirmationsupondelivery-------------------------------21.2Nameplateinformation--------------------------------------22.SafetyPrecautions--------------------------------------------22.1Beforedeliveryofcurrent-----------------------------------22.2Indeliveryofcurrent----------------------------------------42.3Inrunning-----------------------------------------------------43.Inverterstandardspecifications----------------------------43.1Individualspecifications------------------------------------43.2Commonspecifications------------------------------------64.Storage&Installation----------------------------------------74.1Storage---------------------------------------------------------74.2Location-------------------------------------------------------74.3Position--------------------------------------------------------85.Wiring----------------------------------------------------------95.1Maincircuitschematicdiagram----------------------------95.2Terminals-----------------------------------------------------105.3StandardConnectionDiagram-----------------------------125.4WiringPrecautions------------------------------------------136.Usingthedigitaloperator------------------------------------156.1Explanationsofthedigitaloperator-----------------------156.2Displaydata--------------------------------------------------176.3Instructionsofthedigitaloperator------------------------18

1

TECORPElectronics HC1-AUserManual

7.TrialOperation------------------------------------------------197.1Inspectionbeforeoperation--------------------------------197.2Trialoperationprocedures---------------------------------198.FunctionList-------------------------------------------------209.Explanationsofthefunctions-------------------------------2710.Maintenance,Inspection&Troubleshooting--------------7210.1Precautionsaboutmaintenanceandinspection--------7210.2RegularInspectionitems----------------------------------7210.3Errorinformationanditstroubleshooting--------------7410.4Erroranditsanalysis--------------------------------------7511.Peripheraldevicesandspecificationsofoptions--------7711.1Peripheraldevices------------------------------------------7711.2Properspecificationsofoptions------------------------7812.Appendices---------------------------------------------------8112.1Applicationdemonstrations-------------------------------81

Thisoperationmanualis1.37versions.Specificationsaresubjecttochangewithoutnoticeforongoingmodificationsandimprovements.

2

TECORPElectronics HC1-AUserManual

1.Introduction

ThankyouforpurchasingourhighqualityHC1-Aseriesinverters.Beforeinstallationandoperationpleasereadtheseinstructionsin

thismanualthoroughly.Foryoursafety,theproductshouldonlybeinstalled,testedandadjustedbyprofessionalpersonnel.Ifyouhaveanyquestionsorproblems,pleasecontactourlocalagency.

Theinformationcontainedinthismanualissubjecttochangewithoutnotice.

WARNING Indicatesprecautionsthat,ifnotavoided,couldresultindeathorseriousinjurytopersonnel.

! CAUTIONIndicatesprecautionsthat,ifnotavoided,couldresultinminorormoderateinjurytopersonnelanddamagetoequipment.

WARNING

●Alwaysturnofftheinputpowersupplybeforewiring.

●DonottouchanyinnerpartoftheinverterwhenthecharginglampisstillonshortlyaftertheACpoweriscutoff.

●Donotchecksignalswhiletheinverterisrunning.

●Donotattempttomodifyoraltertheinverterbyyourself,doingsocanresultinelectricalshockorinjuryorevenexplosion.

●BesuretogroundtheEterminal.

!CAUTION

●Donotperformvoltagewithstandtestsontheinverter.

●NeverconnecttheACmaincircuitpowersupplytooutputterminalsU.VandW.

●ACMOSICisusedinthecontrolboard.HandlethecontrolboardandCMOSICcarefully.TheCMOSICcanbedestroyedbystaticelectricityiftoucheddirectly.

●Installation,testingandmaintenancemustbeperformedby

professionalpersonnel.

●Theinvertershouldbediscardedasindustrialwaste.Avoidburning.1

TECORPElectronics HC1-AUserManual

1.1Receiving

Beforeunpackingpleasecheckthefollowing:

●Inspecttheentireexterioroftheinvertertoseethereareanyscratchesorotherdamageresultingfromshipping.

●Checkifthereisaninverterandanoperationmanualinthepackageassoonasyouopenthepackage.

●Checkthemodelonthenameplateonthesideoftheinvertertoseeifthisistherightmodelyouwant.

●Checkifthereissomethingwrongwiththeinnerparts,wiringandcircuitboard.

●Useascrewdriverorothertoolstocheckfortightness.●Checkifthereisanyotherthingsinthemachine.

●Checkiftheoperatorbuttonsareallright.

●Checkiftheoptionaldeviceyouorderediscontainedinit.

1.2Nameplateinformation

MODEL: HC1A07D543B

INPUT: 3Ph400V50/60Hz

OUTPUT: 3Ph400V17.5A7.5KW

Freq-Range: 0.1~400Hz

TECORPELECTRONICSCO.,LTD.

MODEL:HC1A07D543B

Softwareversion

Voltagegrade43means3phases400V

Invertercapacity,07D5means7.5KW

Serialnumber

Productname

2

TECORPElectronics HC1-AUserManual

2.Safetyprecautions

2.1Beforedeliveryofcurrent

! CAUTION

●ChecktobesurethatthevoltageofthemaincircuitACpowersupplymatchestheratedvoltageoftheinverter.

!CAUTION

●Esymbolisthegroundterminal,Besuretogroundthegroundterminal.

●DonotConnectelectromagneticswitchesorcontactorstotheoutputcircuits.

!WARNING

●R.S.Tterminalsarepowerinputterminals,nevermixedwithU.V.Wterminals.Besurethatthewiringofthemaincircuitiscorrect.

!

!CAUTION

●Alwaysholdthecasewhencarryingtheinverter.Iftheinverterisheldbythefrontcover,themainbodyoftheinvertermayfail,possibleresultingininjury.

●Mounttheinvertertoametalorothernoncombustiblematerial.●Installtheinverterinasafesite,avoidhightemperature,directsunlight,humidairorwater.

●Keeptheinverterfromthereachofchildrenornon-workers.

●Installacoolingfanorothercoolingdevicewheninstallingmorethanoneinvertersinthesameenclosuresothatthetemperatureofthe

X

airenteringtheinverterisbelow40℃.KM ●Checktobesurethatthefrontcover

isattachedbeforeturningonthe

u powersupply.Donotremovethefront

Invertersv M coverduringoperation.

w ●Donotinstalltheinverterinaspacewithexplosivegas.

X

●Iftheinverterisusedatorabove1000maboveseallevel,thecoolingefficiencywillbeworse,sopleaserunitdowngraded.

●Donotconnectcontactorsandrelatedcapacitororvoltagedependentresistoretc,totheoutputcircuits.

●Ifitisamusttoconnectsuchdevices,besurethereisnoinverteroutputwhenoperatingthesedevices.Otherwise,itwillresultindamage

3

TECORPElectronics HC1-AUserManual

totheinverter.Theinstallationdiagramlikethisisforbidden.

●Donotconnectcontactortotheinputcircuits.TheservicelifeoftheinvertercanbemuchlongerifyoustartorstoptheinverterbypressingthebuttonsFORorREV,especiallyinthosefrequentlystartingandstoppconditions.

2.2Indeliveryofcurrent

WARNING

●Donotremoveconnectorsontheinverterwhenindeliveryofcurrent.

●Alwayshavetheprotectivecoverinplacebeforedeliveryofcurrenttoavoidelectricalshock.

2.3Inrunning

WARNING

●Neveraddorremovemotorgroupwhileinrunning,thesurgecurrentitcreatedwillcausedamagetotheinverter,evenburn-upofthemaincircuit.

WARNING

●Neverremovethefrontcoveroftheinverterwhileinrunning.

●Donotcomeclosetothemachinewhenthefaultrestartfunctionisused.Ifthealarmiscleared,themachinemaystartmovingsuddenly.●ThefunctionoftheSTOPbuttoncanonlybeavailableaftersetting.Itisdifferentfromtheemergencystopbutton.Pleasenote.

!CAUTION

●Donottouchtheheatsink,brakingresistor,orBrakingResistorUnit.Thesecanbecomeveryhot.

●Besurethatthemotorandmachineiswithintheapplicablerangesbeforestartingoperation.

●Donotcheckthesignalswhiletheinverterisrunning.

●Becarefulwhenchanginginvertersettings.Theinverterhasbeensettosuitableforgeneralusinginfactory.

●Doconsiderthenoise,vibration,andthespeedlimitofthemotorandthemechanicaldeviceswhentheinverterisrunningatorabovethefrequencyof50Hz.

4

TECORPElectronics HC1-AUserManual

3.StandardSpecifications

3.1IndividualSpecifications

PowerMODEL InputVoltage (KW)

HC1A00D423B 1Φ/3Φ220V 0.4

DriverCapacity(KVA)

1.0

OutputCurrent(A)2.5

SuitableMotor(KW)0.4

HC1A0D7523BHC1A01D523BHC1A02D223BHC1A0D7543BHC1A01D543BHC1A02D243BHC1A03D743BHC1A05D543BHC1A07D543BHC1A001143BHC1A001543BHC1A18D543BHC1A002243BHC1A003043BHC1A003743BHC1A004543BHC1A005543BHC1A007543BHC1A009043BHC1A011043BHC1A013243BHC1A016043BHC1A018543BHC1A020043BHC1A022043BHC1A025043B

HC1A028043B

1Φ/3Φ220V0.752.05.00.751Φ/3Φ220V1.52.87.01.51Φ/3Φ220V2.24.0102.2

3Φ400V 0.75 2.2 2.7 0.753Φ400V1.5 3.2 4.01.53Φ400V2.2 4.0 5.02.23Φ400V3.7 6.8 8.53.73Φ400V5.51012.55.53Φ400V7.51417.57.53Φ400V111924113Φ400V152633153Φ400V 18.53240 18.53Φ400V223747223Φ400V305265303Φ400V376480373Φ400V457291453Φ400V5584110553Φ400V75116152753Φ400V90134176903Φ400V1101602101103Φ400V1321932531323Φ400V1602303041603Φ400V1852603401853Φ400V2002903802003Φ400V2203254262203Φ400V250368483250

3Φ400V 280 412 540 280

5

TECORPElectronics HC1-AUserManual

MODEL

HC1A030043BHC1A031543BHC1A037543BHC1A041543B

HC1A045043B

InputVoltage

3Φ400V3Φ400V3Φ400V3Φ400V3Φ400V

Power Driver(KW)Capacity

(KVA)

300 450315 461375 550415 610

450 665

OutputCurrent(A)580

605800880

960

SuitableMotor(KW)300

315375415

450

FrequencyControl

setting.

GeneralControl

3.2CommonSpecifications

ITEM HC1-AControlMethodSPWM

InputPowerSupply

400VPowerSupply:340VAC-460VAC220VPowerSupply:180VAC–250VAC

FrequencyRange 0.10~400.00Hz

Frequency Digital:0.01%(-10~40℃)Accuracy Analog:0.1%(25±10℃)

FrequencySetting Digital:0.01Hz

Resolution Analog:1%ofMaxOperatingFrequencyOutputResolution 0.01Hz

OperatorSetting Press←or∧or∨tosetMethod

AnalogSetting 0-5V/0-10VMethod 4-20mA/0-20mA

Frequencyup/lowerlimit,startfrequency,stoppingOtherfunctions frequency,threeskipfrequenciescanbe

individuallyset.

Acceleration/Dec

0.1-6500sfourselectablecombinationsofelerationtime independentaccelerationanddeceleration

V/FCurve SetV/Fcurveatwill.

TorqueControl

MaxTorque10.0%MaxOutputVoltage.Thestartingtorquecanreach150%at1.0Hz

6multifunctioninputterminalsfor8Multi-function multi-speed,easyPLC,4Accel/Decelinputterminals time,UP/DOWNcommand,external

emergencystop.

6

TECORPElectronics

ProtectionFunction

ITEMCommunicationControlOperatingTemperatureHumidityVibration

InstantaneousovercurrentOverLoad

Motor OverloadProtection

OverVoltage

UnderVoltage

MomentaryPowerLoss

HeatSinkoverheat

Multi-functionoutputterminals

Otherfunctions

Digitaloperatormonitor

HC1-AUserManual

HC1-ARS485

-10~40℃

0-95%relativehumidity0.5Gorlower

Approx.200%ratedcurrent.

Inverter:150%1minute.

Electronicthermaloverloadrelay.

23series:DCbusover400Vdc43series:DCbusover800Vdc

23series:DCbusvoltagedrop200Vdc43series:DCbusvoltagedrop400Vdc

0-2seconds:Theinvertercanberestartedbyspeedsearch.

Protectedbythermistor

5multifunctionoutputterminalsforthedisplayingandwarningofon-running,zerospeed,countingandexternalfaultinformation.AVR,Deceleratingstoporfree-stop,DCbrake,autorestarttracking,easyPLCautoenergysaving,adjustablecarrierFrequency(Max20KHz)etc.

Frequencycommand,outputfrequency,speedoutputcurrent,outputvoltage.DCbusvoltageandrotationdirection.

4.Storage&Installation4.1Storage

Thisproductmustbestoredinitspackageboxbeforeinstallation.Paymoreattentiontothefollowingswheninstorage.

●Itmustbestoredinadryplacewithoutrubbishordust.

7

TECORPElectronics HC1-AUserManual

●Thesuitabletemperatureforstorageisbetween-20℃and+65℃.●Therelativehumidityrequiredis0-95%,nocondensation.

●Thereisnocorrosivegasorliquid.

●It’sbettertolaytheinverterinitsoriginalpackageonashelf.

4.2Location

Note:Theworkingconditionsoftheinverterwillaffectitsservicelife,pleaseinstalltheinverterunderthefollowingconditions.

●Ambientoperatingtemperature-10℃to40℃.●IPrating:IP20forallmodels.

●Protectedfromrainmoisture.●Shieldedfromdirectsunshine.

●Freefrommetallicparticlesandcorrosivegas.●Freefromexcessivevibration.

4.3Positioning

●Theremustbeenoughspaceleftaroundtheinverterforeasymaintenanceandeffectiveventilation.SeeDiagram1.

●Theinvertermustbeinstalledwithheatsinkribsorientedverticallyforeffectiveventilation..

●Ifthereisanyinstabilitywheninstallingtheinverter,pleaseputaflatboardundertheinverterbottombaseandinstallagain.Iftheinverterisinstalledonaloosesurface,stressmaycausedamageinmaincircuit.

●Theinvertershouldbeinstalledonnon-combustiblematerials,suchasironplates.

●Ifseveralinvertersareinstalledtogetherinonecabinet,pleaseaddheatdissipationplatesandprovideenoughspacebetweentheinverters.SeeDiagram2.

120

120

50 HCI-A 50

CAUTION:HighvoltageInaide

WARNING:

!

DonotconnectACpowertooutputturbinals(U.V.W)

Dischargingtimelegreaterthan5ancones.

揅HARGE

DonotLnspectcomponentsunlessInside

lampIsturnedoft.

8 Unit:mm

Diagram1 Diagram2

TECORPElectronics HC1-AUserManual

5.Wiring

5.1Maincircuitschematicdiagram

①Powersupply:VerifythattheinverterratedvoltagecoincideswithACpowersupplyvoltage.

②Nofusebreakerorgroundfaultinterrupter.

③Magneticcontactor

Note:Don’tusethemagneticcontactorasthepowersupplyon/offbuttonfortheinverter.

④ACreactorforpowerfactorimprovement.

HCI-A ⑤TECORPInverter(HC1-Aseries)

CAUTION:HighvoltageInaide

WARNING:

!DonotconnectACpowertooutputturbinals(U.V.W)

Dischargingtimelegreaterthan5ancones.

揅HARGE

DonotLnspectcomponentsunlessInsidelampIsturnedoft.

⑥3phasessquirrelcageinductionmotor.

9

TECORPElectronics HC1-AUserManual

5.2Terminals

5.2.1MainCircuitTerminalsArrangement

HC1A00D423B-HC1A02D223B

HC1A0D7543B-HC1A03D743B E R S T U V W P Pr

HC1A05D543B-HC1A07D543B

E R S T U V W P1 P PR

HC1A001143B-HC1A030043B

R S T E P N U V W

5.2.2ControlcircuitterminalsarrangementFA FB FC EVSPLSPMSPH RST

KAKB UPF DRV+10VI AI ACM

HC1A00D423B-HC1A01D523B

HC1A0D7543B-HC1A02D243B

DCMREVFORAMRS-RS+

FA FB FC KA KB IPV UPF DRV DCM SPL SPM

SPH RST REV FOR +10 VI AI ACM AM RS- RS+HC1A02D223BHC1A03D743B-HC1A07D543B

UPFDRVFORREVDCMRSTSPHSPMSPLP24AM

ACM AI VI +10 EKBEKAEFC EFB EFAHC1A02D223BHC1A03D743B-HC1A07D543B

10

TECORPElectronics HC1-AUserManual

5.2.3Functiondescriptionofmaincircuitterminals

SYMBOL FUNCTION DESCRIPTIONR.S.TInputterminalsofAClinepower.

P.Pr Externalbrakingresistorterminals.P.P1ExternalDCreactorterminals.P.NExternalBrakingunitterminals.

U.V.W Outputterminalstomotor.EGroundterminal.

5.2.4Functiondescriptionofcontrolcircuitterminals

SymbolFORREVRSTSPHSPMSPLDCM

EV(IPV)P24+10VI

AI

ACMDRV

UPFFA(EFA)、FB(EFB)、FC(EFC)KA(EKA)、KB(EKB)AMRS+RS-

FunctionsMulti-functioninput1Multi-functioninput2Multi-functioninput3Multi-functioninput4Multi-functioninput5Multi-functioninput6

Groundcommonforinputterminals

+12Vpowersupply+24Vpowersupply

PowersupplyforanalogfrequencyAnalogfrequencyreferenceinput(voltage)

Analogfrequencyreferenceinput(current)

Commonforanaloginputsignal

Multi-functionoutputterminal1

Multi-functionoutputterminal2

Multi-functionoutputterminal3

Multi-functionoutputterminal4

DigitalfrequencyoutputterminalRS-485communications

FactorysettingForwardrunReverserunReset

HighspeedMediumSpeedLowSpeed

Maxoutputcurrent200mAMaxoutputcurrent200mA+10V

0~+10Vcorrespondingtohighestoperatingfrequency4~20mAcorrespondingtohighestoperatingfrequency

OpticalcoupleoutputDC24V/100mA

FaultRelayoutput(N/OorN/C)3A/250VAC,3A/30VDC

FaultRelayoutput(N/O)3A/250AC,3A/30VDC0-10V

11

TECORPElectronics HC1-AUserManual

5.3StandardConnectionDiagram

Thewholewiringisdividedintotwoparts.Maincircuitterminalconnectionsandcontrolcircuitterminalconnections.Userscanseethemaincircuitterminalsandthecontrolcircuitterminalsafterremovingtheoutercover.Theterminalsmustbeconnectedcorrectlyasthefollowingdiagrams.

ThefollowingdiagramshowsthestandardconnectionofHC1-A.BrakingResistor

P Pr

R U

Acpowersupply S V MMotor

T WE

10KΩ

AnalogCurrentinput

VR(+10V)

VIACM

AI

FORREV

SPH

KA Multi-functionoutput<relayN/0>KB 3A/250VAC3A/30VDC

EV(IPV) +12V

FC Multi-functionoutput<relayN/0N/C>

FA3A/250VACFB3A/30VDC

DRVMulti-functionoutput<OP>

SPM UPF24V/100mASPL DCM

RST AM AnalogfrequencyoutputDCM0~10V

ACM

RS+RS-HC1A00D423B~HC1A02D223B HC1A0D7543B~HC1A03D743B

DcReactor BrakingResistor

P1PPrR

Acpowersupply STE

VR(+10V)

U

V WMotorW

KA Multi-functionoutput<RelayN/O>

10KΩ VI

AnalogCurrent ACMinput AI

KB 3A/250VAC3A/30VDCEV(IPV) +12V

FC Multi-functionoutput<RelayN/ON/C>

FA 3A/250VACFOR FB 3A/30VDCREV

SPH DRVMulti-functionoutput<RelayOP>SPM UPF24V/100mA

SPL DCM

RST AM AnalogfrequencyoutputDCM0~10V

12 ACMRS+RS-

HC1A05D543B~HC1A07D543B

TECORPElectronics HC1-AUserManual

Motor

5.4CautionsonWiring5.4.1Formaincircuitwiring

●NoFuseBreakerbetweenthepowersupplyandtheinputterminals(R.S.T).

(Ifusinggroundfaultinterrupter,pleasechoosetheonecorrespondingtohighfrequency)

●NeverconnectACpowertotheoutputterminalsofU.V.Wontheinverter.

●Outputwiresmustn’tbeintouchwiththemetalpartoftheoutercover,oritwillcauseshort-circuit.

●Phase-shiftingcapacitor,LC,RCnoisefilters,etc,canneverbeconnectedbetweenmotorandoutputterminals(U.V.W)

●Themaincircuitwiremustbeenoughfarawayfromothercontrolequipments.

●Ifthereisarelativelylongdistancebetweentheinverterandthemotor,pleaselowerthecarrierfrequency.Becausethehighleakcurrentwillcausedamagetotheinverterandotherequipments.

●Ifthewireismorethan15mfor220Vclassproducts(or30mfor

13

TECORPElectronics HC1-AUserManual

400Vclassproducts)betweentheinverterandthemotor,pleasechooseaACmotorspecialforinvertersoraddaACreactorontheoutputsideoftheinverter,becauseaveryhighdV/dTproducedinthemotorcoilwillcausedamagetotheinsulationofthemotor.

220VClass

400VClass

SpecificationsforNFBandWire

Model Screw WiresizeHC1A00D423B M4 2~5.5HC1A0D7523B M4 2~5.5HC1A01D523B M4 2~5.5HC1A02D223B M4 3.5~5.5HC1A03D723B M4 5.5HC1A0D7543B M4 2~5.5HC1A01D543B M4 2~5.5HC1A02D243B M4 2~5.5HC1A03D743B M4 3.5~5.5HC1A05D543B M4 3.5~5.5HC1A07D543B M5 5.5HC1A001143B M6 8HC1A001543B M6 8HC1A18D543B M6 14HC1A002243B M8 22HC1A003043B M8 22HC1A003743B M8 30HC1A004543B M8 50HC1A005543B M8 38~100HC1A007543B M10 38~100HC1A009043B M10 38~100HC1A011043B M10 60~100HC1A013243B M12 60~100HC1A016043B M12 100~200HC1A018543B M16 250~325HC1A022043B M16 325HC1A030043B M16 250*2p

Note:Theparametersaboveareonlyforreference,notastandard.

5.4.2Forcontrolcircuitwiring(signalline)

●Separatecontrolcircuitwirefrommaincircuitwireandotherhigh-powerlines.

●Usetwisted-pairorshieldedtwisted-paircablesforcontrolcircuitsto

preventoperatingfaults.Thesizeshouldbe0.5-2mm2..14

TECORPElectronics HC1-AUserManual

●Usethecontrolterminalscorrectlyaccordingtoyourneeds.

5.4.3Grounding

●Groundingterminal:E

220Vclass:Thethirdgroundingmethod.(groundingresistanceshouldbe100ohmorlower.)

380Vclass:Specialgroundingmethod.(earthresistanceshouldbe10ohmorlower.)

●Choosegroundingwiresaccordingtotherequirementsoftheelectricequipment.

●Avoidsharinggroundingwirewithotherlargepowerequipment.Thegroundingwireshouldbekeptawayfromthepowersupplywires.

●Thegroundingmethodforseveralinverterstogethershouldbedoneasthefirstandseconddiagrams.Avoidthethirddiagram.

●Theshortergroundingwireisthebetteritis.

(1)Correct (2)Correct (3)Wrong

15

TECORPElectronics HC1-AUserManual

6.DescriptionofDigitalOperator

OperationModeIndicatorsforwardrun,reverserun,frequency,current,Speed.

FORREVHZ A R/min

Forwardorreverserunkey F/R

Numericalchangekey

Runkey RUN

PROG

ENTER

STOP

RESET

HC002

OperationModeIndicatorsforweardrun,reverserun,frequency,current,Speed.

FORREVHZAROTT

Forwardorreverserunkey

Numericalchangekey

Runkey

FOR

REV

DISP

RUN

PROG

SET

STOP

HC001

16

TECORPElectronics HC1-AUserManual

6.2Displaystatus

6.2.1Displaystatusdescription

IndicatorFOR

REV

Status ExplanationOnForwardrun

On Reverserun

HZ On DisplaysetfrequencyoroutputfrequencyA On Displayoutputcurrent

ROTT On Displaymotorspeed

HZAOnAROTTOn

HZ ROTT On

DisplayDCvoltageDisplayoutputvoltage

Displaycountingdata

HZAROTT On Displayinvertertemperature

6.2.2Explanationtodatadisplay

Displayitem

050.00

5.5

1440

30.0

CD100

EOC.A

Indicator ¤onHZ

¤A¤

ROTT¤

HZAROTT¤¤¤

HZ¤

Explanation

Presentsetfrequencyoroutputfrequency

Current

Motorspeed

Presentinverterheatsinktemperature

Functionitem

Errorinformation

17

TECORPElectronics HC1-AUserManual

6.3OperationExample

Procedures Data Display Explanation

Poweron

PROG

ENTER

ENTER

PROG

RUN

DISP

DISP

DISP

PROG

F/R

ENTER

STOP

dsp.1flashing→uEr1.3→000.00

CD000

000.00

50.00END→50.00CD001050.00

50.00

50.000.00→50.00

0005.0

01440

050.00

050.00

050.00

030.00

030.00

030.00

FOR Hz

FOR Hz

FOR Hz

FOR Hz

FOR Hz

FOR Hz

FOR Hz

FOR A

FORROTT

FOR Hz

REV Hz

REV Hz

REV Hz

REV Hz

REV Hz

Selfinspectionafterpoweron,showingitsversionnumber(flashing),thenitssetfrequency.

FunctionnumberCd000.

ModifythevalueofFunctionCD000.Display:END→50.00→CD001Withdrawfromtheprogrammingstatus.

Display:Forwardrunstatusandsetfrequency.

Switchingtodisplayrunningfrequency.

Switchingtodisplayoutputcurrent.

Switchingtodisplayrotatingspeed.

Returntomaindisplay,showingsetfrequency.

Switchingtofrequencyadjustablestatus.

Adjustthesetfrequency,thatisthevalueofCD000.

EnterthenewvaluewhichwillberememberedasCD000.

Stop.

Note:(1)meansflashing ¤meanson

18

TECORPElectronics HC1-AUserManual

7.TrialOperation

7.1Theimportantcheckbeforerunning

●Isthereanywrongconnectedwires?Payspecialattentiontotheterminals:U.V.W;

MakesurethepowersupplywiresareconnectedtoR.S.TnotU.V.W.●Isthereanymetalpowderorotherwiresleftonthebaseplateoftheinverterorattheterminals?

●Isthereanyloosenessinthepartsofscrewsandterminals?●Isthereanyshortcircuitorearthfaultintheoutputparts?

7.2Trialoperationprocedures

¤

¤ ¤

¤

Trialoperationcanbecarriedoutbythedigitaloperator.Generally,trialoperationisdoneat5.00Hz.

Procedures DataDisplay Indicator Explanations

dsp1.1→uEr1.3

000.00

FORHz

¤

POWERON

Selfinspectionafterpoweron,displayversionnumber,atlastdisplaysetfrequency.

000.00

FORHz Switchingtodataadjustable¤ status.

050.00

↓ FORHz Setanewfrequencyvaluethat←△¤ isthenewCD000value.

ENTER 050.00 FORHz Confirmthisnewsetting.

RUN 050.00 FORHz Runningat50Hz.STOP050.00 FORHz Stop.

Note:¤meansindicatoron, meansindicatorflashing0Meansthenumberflashing

19

TECORPElectronics HC1-AUserManual

8.Functionlist

code

ParameterandFunctionList(Part1)

ItemFunction Function

CD000MainfrequencyCD001MaxoutputvoltageCD002Basefrequency

CD003VoltageatmediumfrequencyCD004Mediumfrequency

CD005VoltageatlowestfrequencyCD006Lowestfrequency

Basicparameter

CD007MaxoperatingfrequencyCD008FrequencyupperlimitCD009FrequencylowerlimitCD010Parameterlockselect

CD011Factorysetting

CD012Accel.Time1CD013Decel.Time1CD014Accel.Time2CD015Decel.Time2CD016Accel.Time3CD017Decel.Time3CD018Accel.Time4CD019Decel.Time4CD020

∫ ReservedCD030

Setrange&functionFactoryexplanationSetting

0.00~400.00Hz 0.000.1V—*220/3800.01~400.00Hz50.000.1V—*15/27.50.01~400.00Hz 2.500.1~50.0V8.0/13.50.01~20.00Hz 0.5050.00~400.00Hz50.000.01~400.00Hz50.000.00~400.00Hz 0.000:invalid1:valid000~10onlyNo.08

meanstoresetto 00factorysetting

0.1~6500.0S 10.0/25

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论