杭州铁路东站枢纽西广场机电安装工程防雷接地工程专项施工方案编制:审核:审批:中建三局建设工程股份有限公司(沪)201132日杭州铁路东站西广场·机电安装工程 防雷接地工程施工方案目录目 录····································································································-1-1·······························································································-2-1.1工程概况·······················································································-2-1.2编制依据·······················································································-2-1.3设计要求·······················································································-3-2·······························································································-5-2.1人员组织结构·················································································-5-2.2施工进度计划·················································································-5-2.3劳动力计划····················································································-6-2.4施工机具·······················································································-6-2.5施工材料计划·················································································-6-3·······························································································-73.1施工流程·······················································································-7-3.2接地装置安装·················································································-7-3.3接地端子预留················································································-10-3.4防雷引下线安装·············································································-12-3.5································································123.6···································································143.7接闪器施工···················································································-15-3.8·································································-16-3.9·········································································164.0················································································-16-4质量保证措施························································································-16-4.1质量及工艺标准·············································································-16-4.2······································································184.3················································································-19-5安全及文明施工·····················································································-19-5.1安全施工······················································································-19-5.2文明施工······················································································-20-中建三局建设工程股份有限公司(沪)

-1-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案工程概述工程概况杭州铁路东站枢纽西广场区杭州市江干区新风路交新井杭州铁路东站枢纽西广场区杭州市江干区新风路交新井工程名称 工程地块配套设施项目 路、新塘路杭州市城东新城建设投资有建设单位 勘察单位 浙江省工程物探勘察限公司浙江明康工程咨询有限公设计单位中南建筑设计院股份有限公司监理单位司质量监督部门杭州市质监站总包单位中建三局建设股份有限公司合同工期914日历天建筑面积428600㎡合同工程投资140581.8088元(建安总/层CD座屋面檐口最高处标额 合同额)数23.58以交通集散为核心,以整合国铁、地铁、公交、出租车工程主要功能和社会车辆等多种交通方式或用途的换乘,实现无缝衔接的交通综合体1.2编制依据业主下发施工图及相关文件杭州铁路东站枢纽西广场区块配套设施项目招标文件及答疑文件,电气工程施工图纸;业主、设计、监理和施工单位四方签认的图纸会审记录。我国现行的法律法规、规范、标准及图集序号序号1名称编号《中华人民共和国建筑法》国家法律中建三局建设工程股份有限公司(沪) -2-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案2《建设工程质量管理条例》国家法规3《建筑电气工程施工质量验收规范》GB50303-20024《建筑物防雷设施安装》07D501—15《等电位联结安装》02D501—26《利用建筑物金属体做防雷及接地装置安装》03D501—37《接地装置安装》03D501—4设计要求防雷设计;防雷、电气、消防、弱电和信1欧姆。接闪器:沿屋顶、女儿墙四周用¢12镀锌圆钢敷设避雷带做接10m×10m12m×8m突出屋面的金属物体(铁爬梯、水管、透气管等,加装独立小针,并与就近的避雷带相连。防侧雷击:建筑物应每层利用周边连通之圈梁钢筋作均压环;45米以上外墙上的金属门窗、金属栏杆、幕墙金属构架等与均压环相连接。2D16的钢筋为一组作引18米,上与避雷带,下与基础基地装置连接。防雷电波侵入措施:所有进入建筑物的电缆金属外皮、钢管及各种金属管道应在进出口处就近与接地装置连接。垂直敷设的金属管道上下端与防雷系统连接。防雷击电磁脉冲保护措施:变压器高低压侧各相装设避雷器;各层主配电箱以及重要设备配电箱,屋顶的配电箱设浪涌保护器,并与防雷分界处作等电位连接;弱电机房配电箱以及进线处设浪涌保护器。中建三局建设工程股份有限公司(沪) -3-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案接地装置:利用基础内钢筋作接地装置,利用结构柱、地梁、桩基、底板等内部主筋连通作自然接地体,结构基础钢筋(16mm4根。接地设计系统接地等共用防雷基础接地装置。接地电阻不大于1欧姆。TN-S100*100*10的预埋钢板通过柱内主筋与基础钢筋连接。变电所内采用40*4300mm干线均应与接地干线连接,变电所内设接地端子箱,变压器中性点40*4300mmD563。各弱电系统工作接地分别采用绝缘铜芯线引至接地端子箱。通过接地端子箱与基础钢筋连接。等电位联结:建筑物内所有设备外露可导电部分和装置外可导电部分均应可靠接地(PE02D501-2建筑物内所有管道井均设置接地端子;端子;(弱电机房等)均设置接地端子,以供设备、SPD等电位联结用;有水暖管道的安装通道设置接地端子;200mm明装,其与中建三局建设工程股份有限公司(沪) -4-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案结构主钢筋引下线的连接采用40x4镀锌扁钢焊接连通;M型结构设计,电子信息设备除连接PE线作为保护接地外,还采用两条不同长度的导线以最近20.5地标志。施工部署人员组织结构管理组织机构如下图:王涛王涛技术负责人张海军现场负责人周学军电气施工员袁铭骏、兰吉永中建三局建设工程股份有限公司(沪)施工班组长金立强杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案施工进度计划其他施工的情况下完成防雷接地的施工工作。劳动力计划要求,统一调整技术力量及劳动力。确保施工质量及工程进度。见下表:序号序号工种配合阶段(人)安装高峰阶段(人)收尾阶段(人)1电工2212电焊工2413综合工122施工机具按照施工计划,将开工前及开工后近期需使用的施工机具及时组织进场,以确保工程按期完成。见下表:名称单位数量电焊机(BX1-500型)台2切割机把1电锤把1手枪钻把1角向磨光机台4剪线钳台2接地电阻测试表(ZC29B-2型)只2其他工具批1中建三局建设工程股份有限公司(沪) -6-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案施工材料计划材料计划如下表:序号材料名称规格型号单位数量1镀锌扁钢-40*4米/2钢锌扁钢-25*4米/3镀锌圆钢φ10米/4镀锌圆钢φ12米/5钢板100*100*10KG/施工方案施工流程人员设备进场人员设备进场接地装置安装接地端子预留防雷引下线安装均压环及门窗接地安装接地电阻测试箱安装接闪器安装变配电房及弱电机房接地建筑物等电位联结接地电阻测试中建三局建设工程股份有限公司(沪) -7-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案接地装置安装等内部的主筋连通做自然接地体,结构基础钢筋(每处直径不小于16mm,4)一律采用焊接方式进行可靠连接。接地网干线内主筋的跨接416mm搭接,或用相同截面积的扁钢连接,在主筋螺纹连接处用不小于Φ12跨接处理。并在接地干线纵横交叉处,横筋与纵筋进行连通跨接。图1横筋螺纹连接处跨接处理图2纵横筋跨接示意图中建三局建设工程股份有限公司(沪) -8-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案接地网干线与桩基主筋的搭接2244接地电阻要求。图3桩基内主筋与接地横筋的跨接中建三局建设工程股份有限公司(沪) -9-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案在组合柱处横筋与竖筋可靠焊接。焊接时,搭接长度应符合施工工艺的要求。接地装置的电阻测试接地装置安装完毕后应进行接地电阻的测试工作。接地电阻测试仪采用ZC28B-21图4接地电阻测试仪的接线图中建三局建设工程股份有限公司(沪) -10-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案接地端子预留根据接地设计要求,电梯基坑、设备用房等位置需预留接地端子。定位最近的接地主筋。然后利用结构内主筋由接地装置引上至接地端子所在位置。图5接地端子扁钢接地点引出示意图中建三局建设工程股份有限公司(沪) -11-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案利用圆钢做过渡跨接引出考虑结构内主筋多为螺纹钢,在与扁钢焊接时,难以保证焊接质量,采取用圆钢过渡跨接。待结构浇筑完毕后露出混泥土部分应做好防腐处理。图6利用圆钢过渡跨接中建三局建设工程股份有限公司(沪) -12-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案防雷引下线安装216mm18米,上与避雷带,下与基础基地装置连接。置焊接。图7接地横主筋与引下线的跨接示意图均压环及门窗接地的安装45不小于Φ12的圆钢做跨接处理。中建三局建设工程股份有限公司(沪) -13-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案图8防雷引下线与被利用做均压环的圈梁主筋的跨接示意图图9铝合金窗框的接地做法中建三局建设工程股份有限公司(沪) -14-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案10金属门框的接地做法11扶手或栏杆接地做法接地电阻测试箱的安装0.8¢12中建三局建设工程股份有限公司(沪) -15-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案8cm上打不小于ф8mm志。图12暗装接地电阻测试箱做法接闪器施工本工程属二类防雷建筑物,天面采用避雷带(明敷)构主筋组成的避雷网格(10m×10m12m×8m)防止直中建三局建设工程股份有限公司(沪) -16-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案击雷,明敷避雷带采用Φ12镀锌圆钢,支持卡间距不超过1.5m转弯处不超过0.5m,避雷带及避雷网格均须与防雷引下线做好焊接连通。变配电房及弱电机房接地40X4型接地。因此,需要事先向室内引入接地点(不少于两点面及地板完成后还能找出。建筑物等电位连接公用设施的上、下水、煤气等金属管道、建筑物金属结构采用-40×4镀锌扁钢由总等电位箱并在连接处引出-40x4扁钢引至接地母带与其可靠焊接。(2)户内卫生间局部等电位箱采用-25×4ф80.3米处。4.0接地电阻测试在防雷接地网系统连接形成后,接地电阻进行测试,要求测试电阻不大于1欧姆。并做好相应的记录。然后申请杭州市防雷检测站进行测试验收。质量保证措施质量及工艺标准钢材连接搭接倍数要求钢质接地装置宜采用焊接连接,其搭接长度应符合下列规定:1、扁钢与扁钢搭接为扁钢宽度的2倍,三面施焊;中建三局建设工程股份有限公司(沪) -17-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案26倍,双面施焊;36倍,双面施焊;4、扁钢和圆钢与钢管、角钢互相焊接时,除应在接触部位两侧施焊外,还应增加圆钢搭接件;5、焊接部位除埋在混凝土外均作防腐处理。有良好的导电性。各类焊接的要求平焊弧长度等,通过焊接工艺试验验证。牢固,焊缝周围不得有油污、锈物。焊条保温桶内,随用随取。焊接电流:根据焊件厚度、焊接层次、焊条型号、直径、焊工熟练程度等因素,选择适宜的焊接电流。引弧:角焊缝起落弧点应在焊缝端部,宜大于10mm2~4mm15~20mm回到焊缝起始处,把熔池填满到要求的厚度后,方可向前施焊。罩内看熔池中铁水与熔渣保持等距离(2~3mm)为宜。定不变,酸性焊条一般为3~4mm,碱性焊条一般为2~3mm为宜。中建三局建设工程股份有限公司(沪) -18-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案45°等时,焊条与较厚焊件一侧夹角应大于焊条与较薄焊件一侧夹角。方向带弧,使弧坑甩在焊道里边,以防弧坑咬肉。焊接完毕,应采用气割切除弧板,并修磨平整,不许用锤击落。(包括外观及焊缝尺寸等)确无问题后,方可转移地点继续焊接。立焊:基本操作工艺过程与平焊相同,但应注意下述问题:10%~15%。2~3mm。45°大于较薄一侧的夹角。焊条应与垂直面形成60°~80°角,使电弧略向上,吹向熔池中心。央停弧。严禁使弧坑甩在一边。为了防止咬肉,应压低电弧变换焊条角度,使焊条与焊件垂直或由弧稍向下吹。横焊:10%~15%,2~4mm70°~80°,防止铁水下坠。根据两焊件的厚度不同,可适当调整焊条角度,焊条与焊接前进方向为70°~90°。仰焊基本与立焊、横焊相同,其焊条与焊件的夹角和焊件厚度有关,焊条与焊接方向成70°~80°角,宜用小电流、短弧焊接。中建三局建设工程股份有限公司(沪) -19-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案质量通病及防治措施1、尺寸偏差2、焊瘤a)熔池下部出现“小鼓肚”时,可利用焊条左右摆动和挑弧动作加以控制。b)在搭接接头立焊时,焊接电流应比平焊适当减少,焊条左右摆动时在中间部位走的快些,两边稍慢些。3、咬边度和运弧的方法。4、引上线的制作有专人负责,连接要同侧、同标高。色带宽度、方向一致。5、过变形缝、沉降缝处的接地干线及避雷带要做补偿处理。质量保证措施收,按“建筑安装工程质量评定统一标准(GBJ300-8”进行质量评定。必须严格按图纸及施工方案施工,施工方案必须经监理批准。对施工班组进行技术交底,必须交到每一个操作工人。每道工序完成后,必须经过自检合格后,报请相关工长验收,工长验砼浇筑。方可隐蔽。检测报告及合格证等。中建三局建设工程股份有限公司(沪) -20-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案安全及文明施工安全施工工人进场必须接受项目经理部组织的安全教育及安全考核。必须对工人进行安全交底,必须有每一个工人的签名。每天上班前应开班前会,并有记录。目经理部有关的安全法律、法规、操作规程及规章制度执行。带。施工地点及附近的洞口必须封堵,防止高空坠落。施工现场严禁吸烟,严禁饮酒,不许打架,戏闹。不许翻越栏杆。严禁从高处向下扔东西。现场接电必须由专职维护电工进行,严禁私拉乱接。电线、电缆等不许拖地。使用手持电动工具前必须检查其性能,保证良好。特种作业必须持证上岗。电气焊施工前必须开动火证,有专人看火,带灭火器。电焊机不许放置在雨中及潮湿地面上。电焊机必须双线到位。潮湿地点作业应穿绝缘胶鞋。36V低压电。文明施工进入施工现场必须佩带出入证。进入现场应衣帽整齐。施工现场严禁随地大小便。中建三局建设工程股份有限公司(沪) -21-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案施工现场应做好自身及其他专业的成品保护工作。料。材料应码放整齐,并挂好标识牌。中建三局建设工程股份有限公司(沪) -22-杭州铁路东站西广场·机电安装工程 防雷接地工程施工方案目录目 录····································································································-1-1·······························································································-2-1.1工程概况·······················································································-2-1.2编制依据·······················································································-2-1.3设计要求·······················································································-3-2·······························································································-5-2.1人员组织结构·················································································-5-2.2施工进度计划·················································································-5-2.3劳动力计划····················································································-6-2.4施工机具·······················································································-6-2.5施工材料计划·················································································-6-3·······························································································-73.1施工流程·······················································································-7-3.2接地装置安装·················································································-7-3.3接地端子预留················································································-10-3.4防雷引下线安装·············································································-12-3.5································································123.6···································································143.7接闪器施工···················································································-15-3.8·································································-16-3.9·········································································164.0················································································-16-4质量保证措施························································································-16-4.1质量及工艺标准·············································································-16-4.2······································································184.3················································································-19-5安全及文明施工·····················································································-19-5.1安全施工······················································································-19-5.2文明施工······················································································-20-中建三局建设工程股份有限公司(沪)

-1-杭州铁路东站西广场·机电安装工程 防雷接地工程施工方案工程概述工程概况工程建设概况一览表工程名称

杭州铁路东站枢纽西广场区块配套设施项目

工程地址

杭州市江干区新风路交新井路、新塘路

杭州市城东新城建设投资有限公司中南建筑设计院股份有限公司

勘察单位 浙江省工程物探勘察院浙江明康工程咨询有限公监理单位司质量监督部门杭州市质监站

总包单位

中建三局建设股份有限公司合同工期

914日历天140581.8088元(建安总

建筑面积建筑高度/层

428600㎡C座、D座屋面檐口最高处标额 合同额)数23.58以交通集散为核心,以整合国铁、地铁、公交、出租车工程主要功能和社会车辆等多种交通方式或用途的换乘,实现无缝衔接的交通综合体1.2编制依据业主下发施工图及相关文件纸;业主、设计、监理和施工单位四方签认的图纸会审记录。我国现行的法律法规、规范、标准及图集序号 名 称《中华人民共和国建筑法》《建设工程质量管理条例》

编 号中建三局建设工程股份有限公司(沪)

-2-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案3《建筑电气工程施工质量验收规范》GB50303-20024《建筑物防雷设施安装》07D501—15《等电位联结安装》02D501—26《利用建筑物金属体做防雷及接地装置安装》03D501—37《接地装置安装》03D501—4设计要求防雷设计;防雷、电气、消防、弱电和信息系统共1欧姆。接闪器:沿屋顶、女儿墙四周用¢12镀锌圆钢敷设避雷带做接闪器,网10m×10m12m×8m。突出屋面的金属物体(如铁爬梯、水管、透气管等,均与就近的避雷带相连。突出屋面的非金属物体(如烟囱等立小针,并与就近的避雷带相连。防侧雷击:建筑物应每层利用周边连通之圈梁钢筋作均压环;并将地面45米以上外墙上的金属门窗、金属栏杆、幕墙金属构架等与均压环相连接。2D1618米,上与避雷带,下与基础基地装置连接。接;弱电机房配电箱以及进线处设浪涌保护器。接地装置:利用基础内钢筋作接地装置,利用结构柱、地梁、桩基、底(4根。中建三局建设工程股份有限公司(沪) -3-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案接地设计本工程采用共用接地系统,即变压器中性点接地、保护接地及弱电系统接地等共用防雷基础接地装置。接地电阻不大于1欧姆。大楼内电气线路采用 TN-S接地系统。在变电所内设置总接地点,用100*100*10的预埋钢板通过柱内主筋与基础钢筋连接变电所内采用40*4镀锌扁钢敷设接地干线,于墙上距地300mm明敷。接地干线与柱内预埋的接地连接钢板相焊接配电柜底座槽钢变压器外壳低压PE干线均应与接地干线连接变电所内设接地端子箱,变压器中性点接地单独采用40*4镀锡扁铜引至接地端子箱并与端子板联接。等电位接地端子板于墙上距地板面300mm安装。做法详国标D563。各弱电系统工作接地分别采用绝缘铜芯线引至接地端子箱。通过接地端子箱与基础钢筋连接。等电位联结:建筑物内所有设备外露可导电部分和装置外可导电部分均应可靠接地PE02D501-电位联结设计部位及要求:建筑物内所有管道井均设置接地端子;电梯机房、强弱电机房以及电梯井、强弱电竖井均设置接地端子;用电设备集中的场所(机房等)均设置接地端子,以供设备、SPD等电位联结用;有水暖管道的安装通道设置接地端子;200mm40x4镀锌扁钢焊接连通;MPE接地外,还采用两条不同长度的导线以最近距离与等电位联结网络连接。机房内所有设备的金属外壳、金属线槽、各类金属管道、建筑物金属结构、防静电地板等均须进行等电位联结并接地。中建三局建设工程股份有限公司(沪) -4-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案接地电阻检测本项目每栋建筑物均设置不少于20.5饰相一致,并有可靠的防腐措施和明显的接地标志。施工部署人员组织结构管理组织机构如下图:安装经理安装经理王涛技术负责人张海军现场负责人周学军电气施工员袁铭骏、兰吉永施工班组长金立强施工进度计划防雷接地系统工程工期根据施工前总包方提出的总体施工进度要求进行,配合其他专业施工队伍的进度,在现场具备防雷接地施工条件的前提下,在不影响其他施工的情况下完成防雷接地的施工工作。中建三局建设工程股份有限公司(沪) -5-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案劳动力计划根据工程各部位的预算用工量和计划工期,在施工期间,根据工程施工进度要求,统一调整技术力量及劳动力。确保施工质量及工程进度。见下表:序号序号工种配合阶段(人)安装高峰阶段(人)收尾阶段(人)1电工2212电焊工2413综合工122施工机具名称电焊机名称电焊机(BX1-500型切割机电锤剪线钳接地电阻测试表(ZC29B-2型)其他工具单位台把把把台台只批数量21114221施工材料计划材料计划如下表:序号材料名称规格型号单位数量1镀锌扁钢-40*4米/2钢锌扁钢-25*4米/3镀锌圆钢φ10米/4镀锌圆钢φ12米/中建三局建设工程股份有限公司(沪) -6-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案55钢板100*100*10KG/施工方案施工流程人员设备进场人员设备进场接地装置安装接地端子预留防雷引下线安装均压环及门窗接地安装接地电阻测试箱安装接闪器安装变配电房及弱电机房接地建筑物等电位联结接地电阻测试接地装置安装本工程利用建筑物基础钢筋作为接地装置。利用结构柱、地梁、桩基、承台等内部中建三局建设工程股份有限公司(沪) -7-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案的主筋连通做自然接地体,结构基础钢筋(16mm,4一律采用焊接方式进行可靠连接。接地网干线内主筋的跨接根据施工图纸,找出接地网干线所在轴线,待结构底板内的地梁或面筋安装完毕,416mm高低落差的地段,横筋与横筋之间用不小于最细一根横筋的圆钢搭接,或用相同截面积的扁钢连接,在主筋螺纹连接处用不小于Φ12叉处,横筋与纵筋进行连通跨接。1横筋螺纹连接处跨接处理图2纵横筋跨接示意图中建三局建设工程股份有限公司(沪) -8-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案接地网干线与桩基主筋的搭接22¢1244图3桩基内主筋与接地横筋的跨接施工时,密切配合土建施工进度,首先保证横筋是通筋,在土建验筋合格后,在组中建三局建设工程股份有限公司(沪) -9-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案合柱处横筋与竖筋可靠焊接。焊接时,搭接长度应符合施工工艺的要求。接地装置的电阻测试ZC28B-21果多次测试未能满足要求,应增设人工接地极,直至接地电阻满足设计要求为止。图4接地电阻测试仪的接线图接地端子预留根据接地设计要求,电梯基坑、设备用房等位置需预留接地端子。定位根据施工图纸,找出需要设置接地端子的位置。然后从该位置附近找出与之最近的接地主筋。然后利用结构内主筋由接地装置引上至接地端子所在位置。图5接地端子扁钢接地点引出示意图中建三局建设工程股份有限公司(沪) -10-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案利用圆钢做过渡跨接引出考虑结构内主筋多为螺纹钢,在与扁钢焊接时,难以保证焊接质量,采取用圆钢过渡跨接。待结构浇筑完毕后露出混泥土部分应做好防腐处理。图6利用圆钢过渡跨接中建三局建设工程股份有限公司(沪) -11-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案防雷引下线安装216mm米,上与避雷带,下与基础基地装置连接。根据施工图纸,找出引下线所在柱子位置。待土建横梁调整完毕后,进行引下线竖筋与接地网横筋的跨接。被作为引下线的结构主筋要做好油漆标示,主筋套丝处应做好圆钢跨接,通长引上至屋面。上与避雷接闪器焊接,下与接地装置焊接。图7接地横主筋与引下线的跨接示意图均压环及门窗接地的安装452长连通,横筋与横筋之间要保持通长连通,在主筋螺纹连接处用不小于Φ12接处理。图8防雷引下线与被利用做均压环的圈梁主筋的跨接示意图中建三局建设工程股份有限公司(沪) -12-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案图9铝合金窗框的接地做法中建三局建设工程股份有限公司(沪) -13-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案1011接地电阻测试箱的安装0.8¢12中建三局建设工程股份有限公司(沪) -14-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案圆孔后预留镀锌螺栓。测试箱加盖面板,做出接地标志。图12暗装接地电阻测试箱做法接闪器施工(明敷成的避雷网格(10m×10m12m×8m)Φ121.5m0.5m雷网格均须与防雷引下线做好焊接连通。中建三局建设工程股份有限公司(沪) -15-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案变配电房及弱电机房接地根据设计图纸要求,弱电机房和配电室做均压等电位连接,沿室内周围敷设一圈40X4热镀锌扁钢作为均压带,室内各接地点就近与均压带连接,形成M(不少于两点建筑物等电位连接(1)-40×4由总等电位箱(MEB)引至进户钢管处,采用等电位卡子与钢管连接。并在连接处引出-40x4扁钢引至接地母带与其可靠焊接。(2)户内卫生间局部等电位箱采用-25×4ф80.3米处。4.0接地电阻测试在防雷接地网系统连接形成后,接地电阻进行测试,要求测试电阻不大于1欧姆。并做好相应的记录。然后申请杭州市防雷检测站进行测试验收。质量保证措施质量及工艺标准钢材连接搭接倍数要求钢质接地装置宜采用焊接连接,其搭接长度应符合下列规定:12倍,三面施焊;26倍,双面施焊;36倍,双面施焊;4、扁钢和圆钢与钢管、角钢互相焊接时,除应在接触部位两侧施焊外,还应增加圆钢搭接件;中建三局建设工程股份有限公司(沪) -16-杭州铁路东站西广场•机电安装工程 防雷接地工程施工方案5、焊接部位除埋在混凝土外均作防腐处理。接地装置连接应可靠,连接处不应松动、脱焊、接触不良。均压环与金属管道等自然接地体的连接,应采用焊接。如焊接有困难时,可采用卡

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论